Three lintel types
GOST 948-2016 identifies PB bar lintels, PP slab lintels and PG beam lintels with a ledge. Bar lintels are narrow rectangular elements, slab lintels are wider, and beam lintels accommodate a specific bearing detail.
How to read a designation
The letters identify the lintel type. The numeric groups describe its size and load class. Use the manufacturer’s schedule to look up exact dimensions, reinforcement and rated load.
Match the opening and load
Start with the clear opening and the required bearing at each end. The wall thickness determines the lintel width or the combination of elements. Check the design load, including any floor loads, against the rated load listed for the product. Ask for an engineered detail where a standard size is unsuitable.
Standard range examples
| Code | Type | Section (mm) | Length (mm) | Load or feature | Opening |
|---|---|---|---|---|---|
| 1PB10-1 | PB | 120 × 65 | 1,030 | 100 kgf/m | Up to 1.0 m |
| 1PB13-1 | PB | 120 × 65 | 1,290 | 100 kgf/m | Up to 1.2 m |
| 2PB17-2 | PB | 120 × 140 | 1,680 | 200 kgf/m | Up to 1.5 m |
| 2PB19-3 | PB | 120 × 140 | 1,940 | 300 kgf/m | Up to 1.7 m |
| 2PB22-3 | PB | 120 × 140 | 2,200 | 300 kgf/m | Up to 2.0 m |
| 2PB26-4 | PB | 120 × 140 | 2,590 | 400 kgf/m | Up to 2.4 m |
| 3PB18-37 | PB | 120 × 220 | 1,810 | 3,700 kgf/m | Up to 1.6 m |
| 5PB21-27 | PB | 250 × 220 | 2,070 | 2,700 kgf/m | Up to 1.9 m |
| 1PP12-3 | PP | 380 × 65 | 1,290 | 300 kgf/m | Up to 1.1 m |
| 5PP14-4 | PP | 510 × 140 | 1,420 | 400 kgf/m | Up to 1.3 m |
| 5PP18-8 | PP | 510 × 140 | 1,810 | 800 kgf/m | Up to 1.7 m |
| 5PP21-13 | PP | 510 × 140 | 2,070 | 1,300 kgf/m | Up to 2.0 m |
| 8PP18-71 | PP | 510 × 220 | 1,810 | 7,100 kgf/m | Up to 1.7 m |
| 2PG17-3 | PG | 250 × 290 | 1,680 | With ledge | Up to 1.5 m |
| 5PG21-7 | PG | 380 × 290 | 2,070 | With ledge | Up to 1.9 m |
Before purchase
Check the model, dimensions, condition and batch documents. Confirm lifting and delivery arrangements. Send the opening schedule and structural drawings when asking for a quotation.
Frequently asked questions
How many lintels do I need?
Use the opening schedule. Depending on the wall cross-section, an opening may use one wider element or several narrow elements.
Can a lintel be shortened?
Cutting a precast lintel alters its reinforcement and structural performance. Order a suitable size or an approved custom element.
What does the number after the dash mean?
It refers to the load designation. In the source example, 2PB19-3 is listed for 300 kgf/m.
Can I order a non-standard lintel?
Yes. Send working drawings with the required length, section and reinforcement details.