In this guide
Components of a shared shaft
A duct carries extract air from the room. A ventilation block is a factory-made element with preformed channels. Branch ducts from individual flats may connect to a common shaft that discharges above the roof. Some designs use a warm attic as part of the extract system.
Natural draught needs replacement air
Temperature differences and wind create a pressure difference. Outside air enters habitable rooms and flows towards the kitchen and sanitary rooms. Airtight windows, blocked grilles or restrictions in the shaft can reduce airflow and cause reverse draught.
Airflow by room
| Room | Airflow |
|---|---|
| Kitchen with electric cooker | 60 m³/h |
| Kitchen with gas cooker | 100 m³/h |
| Bathroom, shower room or combined bathroom | 50 m³/h |
| Separate toilet or laundry room | 25 m³/h |
| Store or dressing room | 0.2 air changes per hour |
Selecting blocks and checking installation
Start with the ventilation design, record each branch airflow and match the channel layout to the shaft envelope. Check transitions, site handling and roof termination before placing the order. During installation, align the openings, fill and seal joints, and remove mortar that protrudes into the duct. Inspect the shaft and retain the batch documentation before closing it up.
Masonry, concrete and metal options
The source compares brickwork, conventional precast concrete blocks, steel ducts and expanded-clay concrete blocks. Compare the shaft footprint, assembly method, tested fire rating and maintenance access for the actual assembly.
Frequently asked questions
What is the difference between a duct and a ventilation block?
The duct is the passage through which air flows. A ventilation block is a factory-made element containing one or more passages.
Can blocks be used with aerated concrete walls?
The shaft needs a load-bearing base and connections specified in the design. Lightweight blocks for low-rise buildings start at 14 kg in the published range.
Does a shared apartment shaft need a fan?
A natural extract system uses draught. Fans belong in a system designed for mechanical extract.
How do I confirm fire resistance?
Use the fire-rating documentation for the specified product and complete shaft assembly.
How much do the blocks cost?